Description

Product Overview

The BRK 7010B is a hardwired, interconnected photoelectric smoke alarm powered primarily by 120 V AC mains electricity and supplemented by a 9 V DC battery backup. It uses a photoelectric sensor to detect smoke from smoldering fires more quickly than ionization alarms, which makes it particularly effective at detecting slow‑burning hazards such as cigarette smoke or smoldering upholstery.

The alarm incorporates advanced features such as OptiPath 360™ sensing technology, a single button test/silence control, and LED indicators that visually communicate power and alarm status. It is designed for easy installation, maintenance, and long‑term reliability.


Key Features
 Photoelectric Smoke Detection

Photoelectric sensing technology detects large particle smoke generated by smoldering fires. This type of detection is less prone to nuisance alarms from cooking or steam compared to ionization detectors and provides reliable early warning in real living environments.

Hardwired AC Power with Battery Backup
  • Primary Power: 120 V AC, 60 Hz mains connection

  • Backup Power: 9 V battery (carbon zinc) ensures continuous operation during power outages

  • The unit continues monitoring even if AC power is lost, providing safety during emergencies.

 Loud Audible Alarm

An 85 dB horn emits a clear alarm that is loud enough to be heard throughout a typical home or dwelling at a distance of about 10 feet — a critical factor for alerting occupants promptly.

 Interconnectivity
  • Up to 18 devices can be interconnected on one circuit

  • Of those, up to 12 can be smoke alarms while the rest may be CO or heat alarms

  • When one unit detects smoke, all interconnected alarms will sound, enhancing household safety coverage.

 OptiPath 360™ Photo Sensor

This patented technology allows the sensor to access the air in all directions around the alarm, improving smoke detection reliability.

 Silence/Test Button

A single, easy‑to‑reach button enables users to:

  • Test the unit’s function by simulating a smoke condition

  • Temporarily silence nuisance alarms caused by cooking or steam
    This helps reduce unnecessary disruptions while maintaining safety readiness.

 LED Status Indicators
  • Green LED: steady light indicates AC power is present

  • Red LED: flashes during alarm or DC (battery) power operation
    This visual feedback helps confirm that the unit is powered and functioning properly.


Installation & Maintenance
Mounting and Wiring

The 7010B is intended for hardwired installation into a standard junction box in a ceiling or wall. It uses a quick‑connect wiring harness so that installation is straightforward for electricians or qualified installers.

The included mounting bracket has keyhole slots that allow installation without removing electrical box screws. A Perfect Mount system ensures the unit can be aligned correctly even if the box is misaligned.

Battery Features
  • The 9 V backup battery is installed in a side‑load compartment that can be accessed without fully removing the alarm from its mount.

  • A battery pull tab ensures the battery remains fresh until activation.

  • Locks are provided to deter battery theft.

Dust Cover

A dust cover protects the sensing chamber during construction or renovation.


Performance & Operation
Environmental Conditions
  • Operating Temperature: approx. 40 °F (4 °C) to 100 °F (38 °C)

  • Humidity Range: 10 % to 90 % RH (relative humidity)
    This enables the alarm to perform reliably under typical household environmental conditions.

Automatic Reset

After a smoke event clears, the alarm automatically resets and returns to standby mode, so continuous monitoring resumes without user intervention.


Applications

The BRK 7010B is suitable for:

  • Residential homes

  • Multi‑family housing

  • Dormitories

  • Hotels and motels

  • Sleeping rooms

  • Institutional facilities such as hospitals

Its photoelectric sensing and interconnect capability make it appropriate for spaces where early detection of smoldering fires is crucial and where building codes require interconnected AC/DC smoke detectors.


Certifications & Standards

The 7010B meets several safety and building code standards including:

  • UL 217 (standard for smoke alarms)

  • CSFM

  • NFPA 72 (National Fire Alarm Code)

  • HUD and FHA model codes
    This compliance ensures the alarm meets widely recognized fire safety requirements for residential and institutional use.


Technical Specifications (Summary)
  • Model: 7010B

  • Type: Photoelectric smoke alarm, hardwired

  • Power: 120 V AC mains with 9 V battery backup

  • Sensor: Photoelectric

  • Alarm Loudness: 85 dB @ 10 ft

  • Interconnect: Up to 18 units (12 smoke alarms)

  • LED Indicators: AC/DC, alarm conditions

  • Operating Temp: 40 °F – 100 °F

  • Humidity Range: 10 % – 90 % RH

  • Dimensions: ~5″ diameter × 2.1″ height

  • Color: White

  • Mounting: Ceiling or wall electrical junction box

  • Approvals: UL217, NFPA, CSFM, HUD

  • Warranty: 10‑year limited warranty